AirCheck G2: Statement of Volatility

 
 
Views: 0
 

Statement of Volatility
Clearing User Data from an AirCheck G2 Wireless Network Tester 
 
 
The AirCheck G2 Wireless Network Tester incorporates volatile and non-volatile memory. Volatile memory is memory whose contents are lost when power is removed. Non-volatile memory is memory whose contents are retained when power is removed. Both memory types can be sanitized to remove data previously stored in memory. The sanitation processes for each memory type are provided below.

Volatile Memory:

Memory type SizeUser-modifiableFunction

System SDRAM            

1GB             
YesProgram execution and measurement data storage 


Process to sanitize:  Power down the instrument and remove the AC power adapter for at least 60 seconds. 
 
Non-Volatile Memory:

Memory type            Size           User-modifiableFunction
EMMC Flash 4GBYesProgram/User data (profiles, sessions, images, logs)
Serial EEPROM32KBNo Manufacturing data (MAC address, serial number)
SPI NOR Flash 2MBNoBoot loader

         
Process to sanitize user-modifiable data:  
1.  Connect the AC power adapter to the AirCheck G2.

2.  From the Home screen, tap Settings (gear icon).

3.  Scroll down and select Device Settings.

4.  Tap Restore Factory Defaults

5.  Tap Yes.  

NOTE: The procedure takes 30 seconds to complete, including an automatic shutdown and reboot. Do not interrupt the process while it is in progress.



Non-Volatile Media:

Memory type            Size             User modifiable   Function
USB Device VariableYesRemovable flash storage or headset connectivity 

 

Process to sanitize:  Cover the port with evidence tape to ensure media devices are not used. If media is present, destroy storage media or perform multiple overwrites.