The EtherScope nXG might exhibit the following behaviors when trying to power the unit on, while it is plugged in for charging:
- If charging, pressing the power button will show the battery level temporarily and then go back to charging. The unit will not fully power on.
- If fully charged, pressing the power button will show the battery level and if fully charged it will power off.
To power the unit on, try one of two things:
- Press and hold the power button longer, in order to boot into normal mode.
- Unplug from the power outlet and press the power button to boot into normal mode.
- Press the power button a second time to power on.